Introduction

Runviewer is used for viewing, graphically, the expected changes in each output across one or more shots, and is shown in Fig. 1. Its use is optional, but can be extremely useful for debugging the behaviour of experiment logic. The output traces are generated directly from the set of hardware instructions stored in a given hdf5 file. This provides a faithful representation of what the hardware will actually do. In effect, runviewer provides a low level representation of the experiment, which complements the high level representation provided by the experiment logic written using the labscript API. As such, runviewer traces provide a way to view the quantisation of outputs, [1] which can be seen in the central_Bq and rb_central_MOT_trap_aom_amp channels in Fig. 1. You can also view the pseudoclock outputs. The ni_clock and novatech_clock channels show the independent clocking of devices from a single PulseBlaster pseudoclock: the NI cards are clocked at the sample rates of the two analog ramps, and the NovaTech DDS9m at the 1 kHz sample rate of a frequency ramp that starts at the ‘PGC’ marker.

The runviewer window with one shot and five channels, zoomed in on 30 ms of the shot

Fig. 1 The runviewer interface, zoomed in on the compression of a MOT and the start of an optical molasses (PGC) stage. The analog outputs central_Bq and rb_central_MOT_trap_aom_amp are ramped in steps of 0.5 ms and 0.25 ms.